Electric lubrication unit · RAASM C30 series
Central lubrication for grease (NLGI 2) and oil (>40 cSt), radial piston pumps, 12/24 V DC and 230 V AC.

Pumps · electric
Electric lubrication unit · RAASM C30 series
Central lubrication for grease (NLGI 2) and oil (>40 cSt), radial piston pumps, 12/24 V DC and 230 V AC.
Applications
With progressive divider
The pump feeds one or more dividers. Each divider splits lubricant across multiple points. Suitable from 5 lubrication points.
Direct without divider
Each pump element feeds one point directly. Up to four points possible. Easy retrofit on existing machines.
Standard equipment · included with every pump
Screw-in, one outlet per element, P/N 3081100, 6.5 mm, M20x1.5.
M20x1.5 hydraulic grease fitting, integrated 150 µm fill filter.
Even grease feed, reduces cavity formation in the reservoir.
Power and signals separated, standard harnessing.
Electrical signal at minimum level, switchable to machine control.
Exploded drawing, spare parts list, wiring diagram, multilingual.
Variants · selection
Voltage
* 24 V DC preferred – compatible with machine controls. 230 V AC: IP55, remote control only.
Reservoir size
Rule of thumb: about 1 L per 5 lubrication points for weekly operation.
Control
* Remote = all functions via external PLC. Standard for new machinery.
Series
C30B15 · 1.5–3 L · 12/24 V DC
C30B18 · 3–8 L · 12/24 V DC / 230 V AC
C30B18 FP · 3.5–10 L · follower plate · grease only
C30B18M · 20–40 L · large systems
Follower plate
Accessories
Relief valve + gauge
System protection, adjustable 100–300 bar. P/N 3081350–3081380 depending on element count.
Adjustable pump elements
Delivery per outlet individually adjustable.
Level monitoring