Progressive divider · RAASM MDV-L

Volumetric monobloc divider, galvanized steel, grease and oil, 6–14 outlets.

Progressive divider RAASM MDV-L – product image from the manufacturer catalog.

Divider · progressive system

Progressive divider · RAASM MDV-L

Volumetric monobloc divider, galvanized steel, grease and oil, 6–14 outlets.

6–14 outlets250 bar grease150 bar oil-25 / +60 °CG 1/4" inlet · G 1/8" outlet

How does the progressive system work?

  1. 1

    The pump pushes lubricant into the divider inlet.

  2. 2

    Inside, pistons operate in a fixed order – each piston delivers a preset volume at its point before the next operates.

  3. 3

    All outlets are fed in sequence – mandatory, without exception.

  4. 4

    If one outlet blocks, the entire system stops – visible at the cycle indicator.

Benefit: one cycle indicator monitors all lubrication points at once.

Standard equipment · every MDV-L

Monobloc design

One-piece galvanized steel – no sectional seals, fewer leak paths.

Adjustable metered volume

Metering screw per outlet: 0.1 / 0.2 / 0.4 cm³ per cycle.

Single or twin outlet

Outlets individually or in pairs – volumes add.

Standardized ports

Inlet G 1/4" (f), outlet G 1/8" (f), BSP throughout.

Bypass-capable

Individual outlets can be bridged – plant stays running during maintenance.

Retrofit cycle indicator

Visual, micro switch or proximity – minimal rework.

Variants

Number of outlets

MDV-L6 · 6MDV-L8 · 8MDV-L10 · 10 *MDV-L12 · 12MDV-L14 · 14

* Most common variant. Beyond 14 points: connect a second divider in series.

Cycle monitoring

NoneVisual AVisual BMicro switch *Proximity

* Micro switch = electrical signal per cycle to PLC. Standard for new plants.

Metering screw (per outlet)

0.1 cm³/cycle0.2 cm³/cycle *0.4 cm³/cycle

* 0.2 cm³ standard fit. Larger bearings may use 0.4 cm³.

Lubricant

Grease NLGI 2Oil >40 cSt

Same divider. Max. pressure: grease 250 bar, oil 150 bar.

Accessories

Micro switch

P/N 3081480 · 1 signal/cycle · PLC-compatible · M12 5-pin cable P/N 3081525.

Proximity sensor

P/N 3081490 · inductive, non-contact · for wet or dusty environments.

Over-pressure gauge with memory

P/N 3081562–3081565 (100–250 bar) · shows pressure spike after decay.

Bypass without outlet

P/N 3080070 · bridge a point without stopping the system.

Bypass with outlet

P/N 3080071 / 3080072 · feed forward or divert a point.

Check valve

P/N 3200083 / 3200084 · prevents backflow on pressure drop.